16. Partitions
Select the corresponding function.
For an overview of functions and their attributes, see the table below.
Function
Meaning
Name
Select this point to rename a partition. Enter the name in the
same way as for zones or output names.
Type
Select this point to define the output mode of the partition.
Properties of each output mode can be found in the next
section.
Exit Delay
Exit delay times
10, 20, 30, 45, 60 or 120 sec.
Entry Delay
Entry delay time
10, 20, 30, 45, 60 or 120 sec.
Response
Response in the event of an alarm in this partition.
Part Set
Behaviour of this partition at internal activation (exit delay).
P.Set FE As
Behaviour of entry/exit zone at internal activation. The
options are as follows:
FE as FE –
The entry/exit zone retains the entry/exit
attribute even for internal activation.
FE as NA –
The entry/exit zone changes its attribute at
internal activation to “Instant Set”.
P.Set ER As
Behaviour of the “Entry Route” zone at internal activation
(ER remains ER or ER becomes FE).
Strobe on Set
Behaviour of activation acknowledgement. The options are
as follows:
OFF – No visual acknowledgement on external siren after
successful activation.
ON – Visual acknowledgement on external siren after
successful activation.
Strobe Follow Unset
Behaviour of deactivation acknowledgement. Programming
is made in the same way as activation acknowledgement.
Strobe on Set
Acknowledgement of enabling.
OFF
After successfully enabling the alarm system, there is no
acoustic acknowledgement of the external siren.
ON
After successfully enabling the alarm system, there is an
acoustic acknowledgement of the external siren.
Strobe on Unset
Acknowledgement of disabling. The configuration is effected
in the same way as the acknowledgement of enabling.
16.1 Partition types
Select the corresponding exit mode.
For an overview of exit modes and their attributes, see the table below.
Function
Meaning
Timed Set
The partition is activated following expiry of the defined exit
time.
User Defined
The partition is activated when a zone is closed with the
entry/exit property. In a closed zone (closed door), the alarm
system waits with enabling until this zone has been opened
and closed again.
Approx. eight seconds after closing the door the system is
enabled.
Do not attempt to use a PIR zone as the input or output for a partition.
PIR wireless detectors have an inactive period after each activation to
save battery power. When a partition is activated (or activated
internally), the PIR detector may still be blocked. During this time, no
signal for completion of the activation process can be sent.
In the installer menu:
Æ
Select Partitions
.