ABUS FU8007 Secvest 2WAY Base Kit Installation User Manual
Page 104

104
Wireless
Wireless frequency:
868.6625 MHz, narrow band
EN 300.220-3, EN 300.330-2
Wireless output:
10 mW
Range:
ca. 30 metres (indoors)
ca. 100 metres (outdoors)
(These values are recommended values. The transmission range of the alarm centre,
detectors and other components is strongly dependent on the installation location and
environment. An exact range measurement can only be made using on-site testing.)
Communication
This product can be connected to an analogue telephone connection (PSTN) or an
analogue extension connection. However, due to differences between telephone
network providers, no guarantees can be made for problem-free operation on every
telephone terminal connection.
This product can use a PSTN line with other telephone or fax equipment.
ARC reports:
Scancom Fast Format Channel, Contact ID
Reports, SIA Level I, SIA Level II, SIA Level III,
Extended SIA Level III and CID in SMS.
Social care reports:
Scancom, Scancom Fast Format, Tunstall
Voice messages:
Up to 44 seconds (one 12 second home message
and four alarm messages of 8 seconds each)
GSM/ISDN/ethernet/GPRS:
Connected extension modules with proprietary
interface between module and alarm centre
The network interface corresponds to the applicable specifications (post-office-
approved throughout Europe)
1995/5/EC certification - “Directive on radio and telecommunications terminal
equipment”
This product has been self-certified for individual pan-European end connections on
the PSTN network according to 1995/5/EC R&TTE guidelines. The product was
designed for use on public national remote networks and compatible extension
systems in other European countries.
If problems occur, first consult Abus-SC. The product has been tested according to
TBR21(ETSI ES203021). As a support aid for the use and operation of terminal
devices which meet these standards, the European Telecommunication Standards
Institute (ETSI) has published a set of guidelines (EG 201 121). These contain
suggestions and other requirements for ensuring network compatibility of TBR21(ETSI
ES203021) terminal devices. The product has been developed according to the
recommendations contained within these guidelines and meets the requirements
completely.
Compatibility to EC standards
This product meets the safety requirements of the 89/336/EEC, 73/23/EEC and
1999/5/EC EC guidelines (comparison and harmonisation across European member
states) on the electromagnetic compatibility and safety of electrical devices used in
certain voltage ranges, plus wireless devices and telecommunication terminal devices.
This product is suitable for use in systems that are constructed according to the Class
2X and Environment Class II requirements in PD 6662 : 2004. This product meets the
Class 2 and Environment Class II requirements detailed in CLC/TS 50131-3:2003. This
product meets the Class 2 and Environment Class II requirements detailed in EN
50131–6:1997. The equipment meets the EN 50136-2-1:1998 and EN 50136-2-2:1998
guidelines. This allows the alarm transmission system to fulfil the EN 50131-1:2006
ATS 2 guidelines under the following conditions:
a) The system is installed according to the installation instructions
b) The connected PSTN works normally
c) The alarm reception is equipped accordingly
This product conforms to the limit values according to EN 55022, Class B, and also the
safety requirements according to EN 60950.
34. Declaration of conformity
The declaration of conformity to the applicable guidelines has been made available
and signed by the technical director of ABUS-SC, Germany. It is available at the end of
this manual.