ABUS FU8007 Secvest 2WAY Base Kit Installation User Manual
Page 46

46
To delete the detector and the zone information, select the Default Zone menu item
and confirm with Next
.
Confirm deletion by pressing Yes
.
13.3 Detector already in use
In exceptional cases, the message“Detector already in use” may be
displayed during training of the detector. This occurs after the training
confirmation is received as the detector sends the signal more than
once.
In this case, the display is meaningless.
Checking the detector:
This detector may have already been trained for another zone. Conduct a walk test to
find out which zone this detector has been trained to.
Go to Installer Menu
Æ Test Æ Walk Test and carry out a walk test by triggering a
tamper contact (T) and an alarm (A).
Some detectors do not have tamper contacts (e.g. smoke detectors)
and only send an alarm (A). The display with the number of tested
zones without tamper contacts remains.
Select Test
Select Walk Test
Trigger a tamper
contact (T) and
an alarm (A).
T and A are displayed next to the trained zone (detector).
13.4 Delete All
Do you want to delete all detectors and zone information?
Number of zones
to be tested
T = Tamper
A = Alarm
Information:
All zones tested
In the installer menu:
Ж
Ж
Select the Add/Del Detectors
menu item.