ABUS FU8007 Secvest 2WAY Base Kit Installation User Manual
Page 86

86
To make a test call once per month, select
Reporting -> ALARMS -> Static Test Call -> Monthly.
Enter a number between 01 and 31 on the display to select the day of the month
where the test call should be made. The wireless alarm centre makes a test call at
01:00 on the selected day.
Please note that the wireless alarm centre makes the call arbitrarily up to 16 minutes
before or after the defined time. This ensures that the alarm reception is not
overloaded with test calls from systems set at the same time.
Select
Reporting -> ALARMS -> Static Test Call -> Disabled
to deactivate static test calls.
20.1.15 Burg-Comms-Rearm
Select whether the alarm centre should reset channel 3 (burglary) of the Fast Format
report following expiration of the delay time and then rearm it in the event of a new
alarm. If this function is enabled, all zones in the alarm state are hidden. If the function
is disabled, then this channel is also disabled until the alarm centre is deactivated and
reset.
20.1.16 Send Tamper as Burg
Select whether the wireless alarm centre should transmit a tamper alarm as a burglar
alarm. This is important since there are command centres that cannot evaluate the
resetting of a tamper alarm. If this function is enabled, then a burglar alarm is
transmitted in the event of a tamper message (BA (SIA) or 130 (contact ID)).
20.1.17 No Transmission
20.2 Social Care
The wireless alarm centre sends a social care message for the following alarm types:
Emergency
The user presses Social Care on the alarm center or activates an emergency call
transmitter (pendant). The wireless alarm centre then reports this to the emergency
call centre with the SOCIAL CARE KEY event (SCANCOM channel 2).
Activity
A zone with the activity monitoring attribute is triggered when inactivity is detected in a
programmed zone (see zone type).
Whilst the system is deactivated, the wireless alarm centre checks whether this zone
reports any activity. If the zone remains inactive for longer than the pre-programmed
time (see point 20.), then the wireless centre reports a medical alarm and sends an
INACTIVITY MESSAGE (SCANCOM channel 3) to the emergency call centre.
When the system is activated, the activity monitoring zone is used as a normal alarm.
Select the corresponding function. For a list of functions and their attributes, see the
table below.
Function
Meaning
Call Mode
Setting for reporting emergency messages.
Primary Telecoms
Settings for the primary transmission path of
emergency messages.
Phone Book
Used for selecting a phone number for transmitting
emergency messages.
Account Numbers
Used for entering the customer account numbers from
the command centre.
Report Type
Used for entering the digital command centre report for
the transmission of emergency calls to the command
centre.
Call Acknowledge
Setting for confirming emergency call transmission.
This setting must only be selected when transmitting to a social care unit
using a digital protocol. For voice message transmission, select the next
menu item (Configuring speech dialler).