ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual
Page 97
97
D
Modus = Zusammenfassung
Ereignis
SIA Code
CID Code
AC LOST
AT
301
AC RESTORE
AR
301‡
ALARM ABORT
BC
406
ANTI MASK ZONE OPEN (2)
BT
380
ANTI MASK ZONE TAMPER (2)
BT
380
ANTI MASK ZONE RESTORED (2)
BJ
380
AUX TROUBLE
YP
-
AUX RESTORED
YQ
-
BATT MISSING
YM
311
BATT RESTORED
YR
311‡
LOW BATT
YT
311
LOW BATT RESTORE
YR
311‡
PARTITION RESET
OR
305
RESET OR
305
Modus = Zwischenmeldungen
Ereignis
SIA Code
CID Code
ARM CL
401
DISARM OP
401
KEYSWITCH DISARM
OS
409
KEYSWITCH ARM
CS
409
Modus = Total
Ereignis
SIA Code
CID Code
DOWNLOAD SUCCESS
RS
412
EXPANDER MISSING
TA
137
EXPANDER MISSING RESTORE
TR
137‡
FORBI MISSING
TA
137
FORBI MISSING RESTORE
TR
137‡
JAMMING XQ
380
PASSWORD DEFAULTS LOADED
RH
-
PROG MODE START
LB
627
PROG MODE END
LS
628
TAMPER USER CODE
JA
461
TD (Time and Day) RESET
JT
625
TX BATTERY TROUBLE
XT
384
USER CODE CHANGED
JV
-
USER CODE DELETED
JX
-
(1) Wenn Befehl 143=1 gesetzt ist, so werden alle CID Codes gesendet. Ist der Befehl 143=0 gesetzt, so werden alle
Befehle, die mit ‡ gekennzeichnet sind, nicht gesendet.
(2) Die Zentrale registriert ein Anti-Mask-Ereignis als einen Anti-Mask-Typ niedriger als dieser tatsächlich ist.