34

UK

Internal alarm (025

n

)

Menu item

Setting

Meaning

025

0

Local alarm following

1

Until

deactivated


Alarm on failed Activation (027

n

)

Menu item

Setting

Meaning

027

0 Internal

Alarm

1

Local

Alarm

Hide state display (028

n

)

Menu item

Setting

Meaning

028

0 Never

hide

1

Hide after 180 secs.

2

Hide 30 sec after code

External alarm display on activated entry
delay (029

n

)

Menu item

Setting

Meaning

029

0 Off

1

On

Panic alarm (030

n

)

Menu item

Setting

Meaning

030

0 Loud

1

Silent

Zone tamper reset (031

n

)

Menu item

Setting

Meaning

031

0

No program code
necessary

1

Program code necessary

Control units and partitions (032

nnnn

)

Menu item

Setting

Meaning

032

A

Assignment of control
unit to partition A

B

Assignment of control
unit to partition B

C

Assignment of control
unit to partition C

D

Assignment of control
unit to partition D

System reset (033

n

)

Menu item

Setting

Meaning

033

0

No program code
necessary

1

Program code necessary

Panic reset (034

n

)

Menu item

Setting

Meaning

034

0 User

reset

1

Program

reset

Hide First Sensor Alarm (035

n

)

Menu item

Setting

Meaning

035

0

Hide first sensor

1

Monitor first sensor

Cancel alarm (036

n

)

Menu item

Setting

Meaning

036

0

User can not cancel false
alarm

1

User can cancel false
alarm

Sabotage report deactivated (037

n

)

Menu item

Setting

Meaning

037

0 Only

internally

1

Internally + central station

System tamper reset (038

n

)

Menu item

Setting

Meaning

038

0 User

reset

1

Program

reset

Exit mode for overall area

(039

n

)

Menu item

Setting

Meaning

039

0 Exit

time

1

Manual

2

Last

door

3

Key

switch

In a partitioned system

1

Exit time

2

Manual

3

Immediate

4

Silent

5

Key switch