ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual
Page 192
88
UK
Fire Z -- Rstr
Zone nn fire alarm reset
Soak Fail Z -- Zone nn sensor test failed
Bell Tamper
Rst
Siren tamper alarm reset
Bell Tamper
Siren tamper alarm triggered
System
Rearmed
System automatically rearmed
System
Startup
System supplied with power and started
Tamper Z --
Zone nn has triggered a panic alarm
Tamper Z --
Restore
Zone nn panic alarm reset
Tech Z --
Alarm
Zone nn has triggered a technical alarm
Tech Z --
Restore
Zone nn alarm reset
Tel Line Fault Error in transmission (not for Terxon S)
Tel Line
Restrore
Transmission error reset
User--
Change User-
-
User nn has changed the user code of
user nn
User-- Delete
User--
User nn has deleted the user code of
user nn
U -- Off-Site
User nn has exited the program menu
U -- On-Site
User nn has entered the program menu
User--
System Reset
User nn has reset the alarm centre
User-- # Set
User nn has activated the alarm centre
(area #)
User-- #
Unset
User nn has deactivated the alarm
centre (area #)
User--
Time/Date
User nn has changed the time and date
User Zone #
Omit
User nn has removed ZN nn from
monitoring
User Zone #
Unomit
User nn has returned ZN nn to
monitoring
Global
Tamper
Only for zone property NC + tamper:
Tamper line (COM A/T) triggered
Global T.
Restore
Tamper line (COM A/T) reset
091 Test output 1
The alarm centre activates output 1 on the centre’s PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
091
.
2. To end the test, press:
092 Test output 2
The alarm centre activates output 2 on the centre’s PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
092
.
2. To end the test, press:
093 Test output 3
The alarm centre activates output 3 on the centre’s PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:
1. On the control unit, enter:
093
.
2. To end the test, press:
094 Test loudspeaker output
The alarm centre activates the output for the optional
loudspeaker on the PCB until it is terminated manually. To
start the test, you must open the program menu. Proceed
as follows:
1. On the control unit, enter:
094
.
2. To end the test, press:
095 Test control unit buzzer
The alarm centre activates the control unit buzzer until it is
terminated manually. To start the test, you must open the
program menu. Proceed as follows:
1. On the control unit, enter:
095
.
2. To end the test, press: