UK

Fire Z -- Rstr

Zone nn fire alarm reset

Soak Fail Z -- Zone nn sensor test failed
Bell Tamper
Rst

Siren tamper alarm reset

Bell Tamper

Siren tamper alarm triggered

System
Rearmed

System automatically rearmed

System
Startup

System supplied with power and started

Tamper Z --

Zone nn has triggered a panic alarm

Tamper Z --
Restore

Zone nn panic alarm reset

Tech Z --
Alarm

Zone nn has triggered a technical alarm

Tech Z --
Restore

Zone nn alarm reset

Tel Line Fault Error in transmission (not for Terxon S)
Tel Line
Restrore

Transmission error reset

User--
Change User-
-

User nn has changed the user code of
user nn

User-- Delete
User--

User nn has deleted the user code of
user nn

U -- Off-Site

User nn has exited the program menu

U -- On-Site

User nn has entered the program menu

User--
System Reset

User nn has reset the alarm centre

User-- # Set

User nn has activated the alarm centre
(area #)

User-- #
Unset

User nn has deactivated the alarm
centre (area #)

User--
Time/Date

User nn has changed the time and date

User Zone #
Omit

User nn has removed ZN nn from
monitoring

User Zone #
Unomit

User nn has returned ZN nn to
monitoring

Global
Tamper

Only for zone property NC + tamper:
Tamper line (COM A/T) triggered

Global T.
Restore

Tamper line (COM A/T) reset

091 Test output 1

The alarm centre activates output 1 on the centre’s PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:

1. On the control unit, enter:

091

.

2. To end the test, press:

092 Test output 2

The alarm centre activates output 2 on the centre’s PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:

1. On the control unit, enter:

092

.

2. To end the test, press:

093 Test output 3

The alarm centre activates output 3 on the centre’s PCB
until it is terminated manually. To start the test, you must
open the program menu. Proceed as follows:

1. On the control unit, enter:

093

.

2. To end the test, press:

094 Test loudspeaker output

The alarm centre activates the output for the optional
loudspeaker on the PCB until it is terminated manually. To
start the test, you must open the program menu. Proceed
as follows:

1. On the control unit, enter:

094

.

2. To end the test, press:

095 Test control unit buzzer

The alarm centre activates the control unit buzzer until it is
terminated manually. To start the test, you must open the
program menu. Proceed as follows:

1. On the control unit, enter:

095

.

2. To end the test, press: