beautypg.com

16 programming – ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual

Page 136

background image

32

UK

16 Programming

16.1 Program

mode

All input in program mode is made via the keypad. The
LCD display gives you information about your input. For
further information about the programming items, see
page 30.

Proceed as follows to change an item:

1. Via the keypad, enter the three-digit number of

the menu item (e.g.,

001

for Zone 1) whose

property you want to view or change. To confirm
your input, press the Enter key

.

The selected menu item is shown on the LCD
display.

2. To leave a setting unchanged, press the Enter

key

.

3. Otherwise, enter the new value via the keypad.

You can see possible values in the programming
table.

The new property is displayed.

4. To confirm and save the new value, press the

Enter key

.


5. You can select a new item only if the LCD display

shows Installer Mode.


To exit the program menu:

1. The LCD display shows: Installer Mode.

2. Enter

99 a

nd confirm your entry by pressing the

Enter key .

The LCD display shows: Exit Eng. ?

3. Confirm your input by pressing the Enter key

.

To cancel your input, press the X key

.


4. After you confirm your input with the Enter key

, the alarm centre checks the current status of

the system. If everything is correct, the alarm
centre returns to normal operating state.

You have exited the program menu. The alarm
centre is now deactivated.

5. If there are any system faults, these are now

displayed. Possible faults are:

- Tamper contact of the alarm centre or

control unit open

- No mains or battery power available

- A zone is open that triggers immediate

alarm even when the alarm centre is
deactivated (24 hour, fire, tamper).

If there is a system fault, the program mode is not
exited. First clear all displayed system faults and
repeat the steps listed above.


Factory settings

Program code/
Master code:

7890


User code 1/
Admin code:
1234

User codes 2–16:

X002….X016 (not valid

until setting)


Threat code:

x017 (not valid until setting)