ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual

Page 173

background image

69

UK

33

Unset 4
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).

34

Fire
This output is activated if a fire alarm is
triggered. The output remains active
until the alarm is deactivated.

35

PA
This output is activated if a fire alarm is
triggered. The output remains active
until the alarm is deactivated.

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

082 Relay output OP2

To change the behaviour of relay output OP2 on the alarm
centre PCB:

1. On the control unit, enter:

082

2. The LCD display shows: 082: Strobe

3. Via the keypad, select from the items described

above and enter the function accordingly:

083 Transistor output OP3

To change the behaviour of transistor output OP3 on the
alarm centre PCB:

1. On the control unit, enter:

083

2. The LCD display shows: 083: Set Latch

3. Via the keypad, select from the items described

above and enter the function accordingly:

085 Burglary output

To change the behaviour of the transistor output on
burglar alarms:

1. On the control unit, enter:

085

2. The LCD display shows: 085: Burg=Latched

3. Via the keypad, select from the following items

and press:

00

Burg=Latched
The output remains activated until the
user or programmer resets the alarm
centre.

01

Burg=Rearm
The output is reset following expiry of
the defined siren duration. It can be
reactivated in the event of a new alarm.


4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

086 Additional entry delay

To change the behaviour of the entry delay time:

1. On the control unit, enter:

086

2. The LCD display shows: 086:Dual Ply OFF

3. Via the keypad, select from the following items

and press:

0

Dual Ply OFF
An alarm is triggered following expiry of
the entry delay time.

1

Dual Ply ON
An internal alarm is triggered following
expiry of the delay time. The user has
another 30 seconds to enter the user
code and deactivate the alarm centre.


4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.