beautypg.com

ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual

Page 112

background image

8

UK

7 Notes on security system


The Terxon MX burglar alarm panel enables you to
configure each of the 8 (max. 32) alarm zones
optimally to suit your operating conditions.
Recommendations:

• Distribute the external detectors in as small groups as

possible to the zones (e.g., ground-floor detector to
zone 1, etc.); activate detectors singly; if possible, use
all zones of the alarm centre.


• The acoustic signal (siren) of the signal transmitter

should be shorter than the visual signal (flashlight).
Alarm times must be set according to local regulations.
(E.g., in Germany, the acoustic alarm must be limited to
3 minutes.)

• The delay time should not be finally set until a practical

test has been conducted.

• Choose a random 4-digit or 6-digit combination for the

user and program code.


• Only persons of trust should be given the code.

• When operating the alarm centre, enter the code in such

a way that it is concealed from persons standing nearby.

• The cable recommended for connecting the

components (minimum diameter: 0.6 mm/wire) is
normally colour-coded.

The user and program codes must be different.

For reasons of clear layout, use the following colour
coding:

Red:

+12V voltage supply

Black: 0V

ground

Yellow: Alarm

contact

Green: Alarm

contact

Brown: Tamper

contact

White: Tamper

contact


• Use distributors when connecting more than one

detector to an alarm zone. Cable extensions can be
soldered or screwed together. Ensure good insulation
(insulating tape, shrink-on tubing) to avoid short-
circuiting and false alarms. See the illustration on the
next page.

• Proceed as follows:

1. Read the operating instructions carefully.
2. Draw up a plan of the object that includes the

installation location of the detectors and the alarm
centre and all cables required.

3. Lay the cables as required.
4. Install the detectors and the alarm centre.
5. Connect the cables to the detectors and the alarm

centre.

6. Connect the power supply (battery, mains).
7. Program

the

device.