ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual
Page 195

91
UK
TELCO2 FAULT RESTORE
LR
-
ZONE OMIT
BB
573
Summary
Event
SIA Code
CID Code
AC LOST
AT
301
AC RESTORE
AR
301‡
ALARM ABORT
BC
406
ANTI MASK ZONE OPEN (2)
BT
380
ANTI MASK ZONE TAMPER (2)
BT
380
ANTI MASK ZONE RESTORED (2)
BJ
380
AUX TROUBLE
YP
-
AUX RESTORED
YQ
-
BATT MISSING
YM
311
BATT RESTORED
YR
311‡
LOW BATT
YT
311
LOW BATT RESTORE
YR
311‡
PARTITION RESET
OR
305
RESET
OR
305
Intermediate
Event
SIA Code
CID Code
ARM
CL
401
DISARM
OP
401
KEYSWITCH DISARM
OS
409
KEYSWITCH ARM
CS
409
Total
Event
SIA Code
CID Code
DOWNLOAD SUCCESS
RS
412
EXPANDER MISSING
TA
137
EXPANDER MISSING RESTORE
TR
137‡
FORBI MISSING
TA
137
FORBI MISSING RESTORE
TR
137‡
JAMMING
XQ
380
PASSWORD DEFAULTS LOADED
RH
-
PROG MODE START
LB
627
PROG MODE END
LS
628
TAMPER USER CODE
JA
461
TD (Time and Day) RESET
JT
625
TX BATTERY TROUBLE
XT
384
USER CODE CHANGED
JV
-
USER CODE DELETED
JX
-
(1) If command 143=1 is set then all CID codes are transmitted. If command 143=0 is set then all commands marked by ‡
are not transmitted.
(2) The alarm centre registers an anti-mask event as an anti-mask type lower than it actually is.