172 prog. pulse outputs (time inactive), 173 prog. pulse outputs (levels inactive), 174 prog. pulse outputs (fire option) – ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual
Page 185: 175 prog. pulse outputs (panic option)
81
UK
2. The LCD display shows: 171: Set 1 ABCD
3. Via the keypad, enter the activation level. A =
overall active, B, C and D for internal active B, C
or D.
4. To confirm, press:
5. The LCD display shows: 170: Set 2 ABCD
6. In the same way, enter activation level 2 via the
keypad.
7. Continue until all levels are entered.
8. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
172 Prog. pulse outputs (time inactive)
The outputs programmed as inactive 1–4 are pulse-
addressed for a predefined time during deactivation of the
alarm centre. First define the time in which these output
are to be active.
1. On the control unit, enter:
172
2. The LCD display shows: 172: Unset 1 01
3. Via the keypad, enter the time duration. Possible
values: are 00 for a latched output or a time
duration from 01 to 12 seconds.
4. To confirm, press:
5. The LCD display shows: 172: Unset 2 01
6. In the same way, enter pulse time 2 via the
keypad.
7. Continue until all times are entered.
8. The control unit acknowledges your input with a
double “beep” tone and shows Installer mode.
173 Prog. pulse outputs (levels inactive)
Define when the outputs are to activated by defining the
type of activation/deactivation (A, B, C, D) for switching
the outputs to active.
1. On the control unit, enter:
173
2. The LCD display shows: 173: Unset 1 ABCD
3. Via the keypad, enter the activation level. A =
overall active, B, C and D for internal active B, C
or D.
4. To confirm, press:
5. The LCD display shows: 173: Unset 2 ABCD
6. In the same way, enter activation level 2 via the
keypad.
7. Continue until all levels are entered.
8. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
174 Prog. pulse outputs (fire option)
Define whether the outputs are also to be activated for fire
alarm by setting the Fire option to ON. Important: Only
those outputs that are activated during deactivation of the
alarm centre can also be activated for fire.
1. On the control unit, enter:
174
2. The LCD display shows: 174: Fire 1 ON
3. Use the keypad to define:
00
=OFF
01
=ON
4. To confirm, press:
5. The LCD display shows: 174: Fire 2 ON
6. In the same way, enter the Fire 2 option via the
keypad.
7. Continue until all outputs are entered.
8. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
175 Prog. pulse outputs (panic option)
Define whether the outputs are also to be activated for
panic alarm by setting the Panic option to ON. Important:
Only those outputs that are activated during deactivation
of the alarm centre can also be activated for panic.
1. On the control unit, enter:
175
2. The LCD display shows: 175: PA 1 ON