022 Changing the volume for internal alarm

For changing the zone termination for the inputs of the
burglar alarm centre. From the program level, do the
following:

1. On the control unit, enter:

022

2. The LCD display shows: 022:ChimeVol=5

3. Via the keypad, select from the following items

and press:

0-9

ChimeVol
Specify the volume of the internal alarm
issued via the control unit and the
(optional) loudspeaker.
Press:

0

off

1

quiet

9

loud

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

023 Remote reset

This function allows a remote reset via the COM interface
or the PC connection. IMPORTANT: System reset by
installer must be activated (function 33 to 1) and CSID
(function 50) must be set.

1. On the control unit, enter:

023

2. The LCD display shows: 023:RemReset OFF

3. Via the keypad, select from the following items

and press:

0

RemReset OFF
Fern Reset AUS

1

RemReset ON
Fern Reset AN

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

After the alarm, the user can switch off the alarm using the
access code, although he can not reset the alarm centre.
The user contacts the central station which identifies him
and transmits a signal back to the alarm centre. The user
can now carry out a reset.

024 Account name

This function shows you the account name. From the
program level, do the following:

1. On the control unit, enter:

024

2. Via

you leave the menu.

3. The control unit shows Installer Mode.

025 Internal alarm

To change the property of the internal alarm:

1. On the control unit, enter:

025

2. The LCD display shows: 025:LS Timed

3. Via the keypad, select from the following items

and press:

0

LS Timed
The internal alarm follows the entered
times for the external siren

1

LS Cont
The internal alarm sounds until the
alarm centre is deactivated.

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.