ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual

Page 162

background image

58

UK

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

054 BVVO monitoring

To change the property of the BVVO monitoring:

1. On the control unit, enter:

054

2. The LCD display shows: 054: BVVO Sup OFF

3. Via the keypad, select from the following items

and press:

0

BVVO Sup OFF
If a radio transmitter can no longer be
reached by the alarm centre then this
reports a monitoring error after 1 hour
(see function 128).

1

BVVO Sup ON
If a radio transmitter can not be reached
for more than 15 minutes then a
warning is displayed on the control unit
if an attempt is made to activate it. If the
transmitter can not be reached for more
than 2 hours then the alarm centre
reports: „detector tampering“, (when
activated) external alram; „monitoring
error“, (when deactivated) internal
alarm.

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

056 Length of access code

To change the property of the length of the access code:

1. On the control unit, enter:

056

2. The LCD display shows: 056: 4 Digit

3. Via the keypad, select from the following items

and press:

0

4 Digit

1

6 Digit

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.


IMPORTANT: Changing the length of the access code
requires that all codes be reset to the factory settings.
From the factory: 4 numbers (1234 for user, 7890 for
installer); 6 numbers (123456 for user, 567890 for
installer).

057 Battery test

To change the property of the battery test:

1. On the control unit, enter:

057

2. The LCD display shows: 057: BattTest OFF

3. Via the keypad, select from the following items

and press:

0

BattTest OFF
No battery test is carried out.

1

BattTest ON
A battery test is carried out if
deactivated or 23 hours after the last
test (neg.: display „battery fault“ in the
control unit + short tone)

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.