beautypg.com

17 technical data – ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual

Page 196

background image

92

17 Technical data

Voltage supply
External

voltage

supply: 230V

AC +/-10% (ambient temperature 20°C)

External

power

consumption:

1.0A

maximum

Internal

voltage

supply:

19VAC

/

-10%

Internal

power

supply:

2.0A

maximum

CPU

power

consumption:

150mA

maximum

Power consumption of control unit:

35mA maximum

Emergency power supply:

12V DC, 7.0Ah lead rechargeable battery


Outputs
Transistor

outputs:

12V

DC, 0.5A maximum, negative switching

Loudspeaker:

2

x

16

Ohm

loudspeakers

parallel

AUX:

12V DC / 0.5A maximum

Relay

outputs:

24V

DC

/

1A

maximum

Additional

Transistor

outputs:

12VDC,

0.05A

max.

Inputs
TR:

Tamper

input

from

siren

Telephone

fault: +12V

DC

if

fault

present

Fuses
F1

12V

AUX:

230V,

1A

quick-acting

F2

battery:

230V,

2A

quick-acting

Specifications
Dimensions:

390mm

x

310mm

x

95mm

(HxWxD)

Weight:

5kg

Internal

time:

+/-

10

min./year,

synchronised

to

mains

frequency

Environment:

-10°C

to

+55°C

max.

96%

humidity