beautypg.com

ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual

Page 151

background image

47

UK

After entering the zone name, enter the zone property.
Zone properties are explained on pages 19 and 20 of
these instructions. Enter the zone property as follows:

1. Enter the zone property via the keypad as follows:

00

NU – Not Used

01

PA – Panic

02

Fr – Fire

03

NA – Immediate

04

24 – 24 hours

05

FE – Entry/exit

06

Er – Entry to follow

07

SA – Shock sensor

08

Tc – Technical zone

09

KB – Keybox

10

SD – Fire alarm

11

KM – Key switch pulse

12

KF – Key switch stable

13

AM – Anti Mask

14

FB – Forbikobler

2. After entering the zone property, enter the area

for which this zone is to be monitored. For an
explanation of areas, see page 20 of these
instrauctinos. Enter the area via the keypad as
follows:

A

This zone is monitored if area A is
active.
The LCD display shows:

a

B

This zone is monitored if area B is
active.
The LCD display shows:

b

C

This zone is monitored if area C is
active.
The LCD display shows:

c

d

This zone is monitored if area D is
active.
The LCD display shows:

d

,

3. Apart from the zone property and the area in

which the zone is to be monitored, there are also
zone attributes. Via the keypad,

enter the zone attributes as follows:

X1

C – door chime
The alarm centre always generates a
tone on the control unit and the
loudspeaker if a zone with this zone
attribute is triggered. This applies only if
the burglar alarm centre is deactivated.
This zone is available for zones with the
properties “immediate”, “entry/exit”,
“entry”, “follow” and “shock sensor”.

X2

S – Sensor test
Zones with this zone attribute are in a
test function. Use this test function if
you think a sensor may trigger a false
alarm. This zone starts a 14-day test. If
this zone triggers an alarm within 14
days, no general alarm state is
declared. The sensor is removed from
monitoring and a message is displayed.
If the zone triggers no alarm within 14
days, the zone test ends, the zone
attribute is deleted and the zone works
normally again.
This zone is available for zones with the
properties “immediate”, “entry to follow”,
“technical” and “shock sensor”.

X3

D – Zone link
Zones with this zone attribute first
trigger an alarm when a further zone
triggers an alarm with 5 minutes or if a
zone is open for at least 10 seconds
(e.g.: magnetic contacts). This function
reduces false alarms from individual
sensors to a minimum, but a burglary
may be detected too late or not at all.
This zone is available for zones with the
properties “immediate”, “entry to follow”.

X4

O – Lock zone
Zones with this zone attribute can be
locked manually by the user and
removed from monitoring.