ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual
Page 190
86
UK
16.5 Examples for a partitioned system
The following example shows a building with an entry area and two office areas. The two office areas are occupied by two
different companies. The entry area is used by both companies.
With a partitioned system, two separate alarm centres are simulated by one alarm centre.
Detector 1 - entry/exit A + B
Detector 2 - entry to follow A + B
Detector 3 – normal alarm A
Detector 4 - normal alarm B
Detector 5 – normal alarm A
Detector 6 - normal alarm B
Detector 7 – normal alarm A
Detector 8 - normal alarm B
When the user of partition A leaves the office, he enters his
4-digit code at the control unit (1234). All detectors intended
for his partition are automatically activated.
Detectors 1 and 2 are only activated when user 2 has also
activated his partition (user code 5678).