ABUS AZ4110 LCD Keypad for Terxon SX_MX Installation User Manual
Page 147
43
UK
User reset after confirmed alarm
(164
n
)
Menu item
Setting
Meaning
164
0 User/Installer
1
User/User
2
Installer/Installer
Duration of active pulse 1 2 3 4
(170
n
n
n
n
)
Menu item
Setting
Meaning
170
00 Latched
output
01 – 12
Pulse duration in
seconds
Switch output active stable
(171
n
n
n
n
)
Menu item
Setting
Meaning
171
A B C D
Activate switch output
for active area
Duration of inactive pulse 1
(172
n
n
n
n
)
Menu item
Setting
Meaning
172
00 latched
output
01 – 12
Pulse duration in
seconds
Switch output inactive stable
(173
n
n
n
n
)
Menu item
Setting
Meaning
173
A B C D
Activate switch output
for inactive area
Switch output for fire
(174
n
n
n
n
)
Menu item
Setting
Meaning
174
0
Switch output off
1
Switch output on
Switch output for panic
(175
n
n
n
n
)
Menu item
Setting
Meaning
175
0
Switch output off
1
Switch output on
Call mode TWG (181
n
)
Menu item
Setting
Meaning
181
0 OFF
1
ON
Last output for settling time
(182
n
)
Menu item
Setting
Meaning
182
07 7
seconds
08 8
seconds
09 9
seconds
10 10
seconds
11 11
seconds
12 12
seconds
Change display time (183
n
)
Menu item
Setting
Meaning
183
Max. 16
locations
C/D – left / right
Fire transmitter (184
n
)
Menu item
Setting
Meaning
184
0 OFF
1
ON
Auto reset key switch (185
n
)
Menu item
Setting
Meaning
185
0 OFF
1
ON
Number of home „beep“ calls
(186
n
)
Menu item
Setting
Meaning
186
nn
00 – 15