Running manual calibrate, Chapter 2 – Printronix SL_T5R Energy Star User Manual
Page 66
66
Chapter
2
Printing Adjustments
Running Manual Calibrate
Manual Calibrate should be performed only when the values derived from
Auto Calibrate fail to improve the media sensors’ ability to sense label length
indicators on the installed media. You must first enable “Admin User” in the
PRINTER CONTROL menu before accessing or initializing Manual Calibrate
in the CALIBRATE CTRL menu.
NOTE:
Verify the Gap/Mark Sensor option (Gap, Mark, Advanced Gap,
Advanced Notch, or Disable) matches the installed media. See
“Sensing Different Media Types” on page 59.
Ensure the media sensors are horizontally positioned to permit
sensing of the label length indicators. See “Positioning the Media
Sensors” on page 54.
Ensure the Print Mode option selected in the QUICK SETUP menu
matches the media installed. Select “Direct” for heat sensitive media
(no ribbon required) or “Transfer” for thermal transfer media (ribbon
required).
If you try to do a Manual Calibrate when Peel-Off Media Handling is
enabled, the LCD will display, “CANNOT CALIBRATE/Disable Peel-
Off.” Before you can do a Manual Calibrate, you must select another
media handling mode.
1.
Press
to place the printer in Menu mode.
2.
Press the
↓ and
↵
keys together until “ENTER SWITCH UNLOCKED”
displays.
3.
Press
until “PRINTER CONTROL” displays.
4.
Press
↑ until “Admin User” displays, then press
+
until “Enable” displays.
183416a
FEED
1023
0767
0511
0255
0000
Paper Out(301)
Gap(160)
Detected Amplitude
of the Antenna
Detected Amplitude
of the Gap
Media Sensor
Position
Indicates Type of Gap/Mark
Sensing Selected
..
.
..
.