Printronix SL_T5R Energy Star User Manual
Page 145
PRINTER CONTROL Submenus
145
4.
If the selection is valid, the display will read, “Enter the new lock key
again.” Press the same combination of keys a second time. If the
selection is invalid, the display will read, “Invalid key selection.” Return to
step 2 and start over.
5.
If the new lock key combination is entered again correctly, the display will
read, “Lock key has been changed.” If it was entered incorrectly, the
display will read, “Validation failed.” Start over at step 1.
6.
After entering the new lock combination successfully, press the PAUSE
key to put the printer back online.
NOTE:
The new lock combination will remain even if the printer is powered
off and back on.
PTX Setup Parse
•
Enable
(factory default). Will parse and execute the PTX SETUP
commands.
•
Ignore
. Will parse the PTX SETUP commands but not act on them.
•
Disable
. Will not parse the PTX SETUP commands so they will print out
as text.
PJL Control
•
Enable
(factory default). Will parse and execute the PJL commands.
•
Disable
. Will not parse the PJL commands; they will not print out as text.
Page Mem Adjust
Page Mem Adjust should be set to the longest form length used on the printer.
User applications that are less than or equal to the default setting of 24 inches
do not need to modify the value. The value resets to the default when the
printer firmware is downloaded and/or the printhead (203 DPI or 300 DPI) is
changed.
The default is 24 inches, the minimum setting is 12 inches, and the maximum
setting is 99 inches. The values adjust by 1 inch increments.
Max Font Buffer
The maximum amount of DRAM allocated to store the global font information
of any resident and downloaded scalable font (e.g. Intellifont, TrueType).
Each font contains its own global font information that is required for all
character generation from that font. Some fonts may require more font buffer
memory than others to generate characters. Insufficient font buffer memory
causes characters to be missing on the page and print blank. If a font needs
more memory for character generation, increase the Max Font Buffer value to
allow the printer to print the missing character.
The range is from 100 to 1800 Kbytes, and the factory default is 1500 Kbytes.