beautypg.com

Printronix SL_T5R Energy Star User Manual

Page 310

background image

310

Chapter

6

Diagnostics for E0xx, Bad NVM, or ILL NVM Errors

27 CU TIMED OUT

Yes

Controller Unit Timed
Out: the printer was not
enabled for one minute
or more on a coax
interface.

Check the cable connection
and host system. (Refer to the
line problem determination
procedures, as recommended
by the host system.)

28 CU NOT ENAB

Yes

Controller Unit Not
Enabled. Poll time-out-
error. The printer was
not polled for one
minute across a coax
interface.

Check the cable connection
and host system. (Refer to the
line problem determination
procedures, as recommended
by the host system.)

33 HEAD OPEN

TIMEOUT

Yes

Status message in the
CT emulation: The
printer was offline more
than 10 minutes, and
the "Intervention
Required" parameter is
set to "Send to Host."

Close and latch the printhead.
Press PAUSE to put the printer
online.

40V POWER FAIL

Yes

+40 VDC: an internal
power failure.

Power off the printer for 15
seconds, then power back on.
If the problem persists, contact
your authorized customer
service representative.

203 DPI Head

Installed

Yes

Normal power-up
message. The printer
is running its
initialization routine
and indicating DPI
resolution of the
installed printhead.

No action required.

300 DPI Head

Installed

Yes

Normal power-up
message. The printer
is running its
initialization routine
and indicating DPI
resolution of the
installed printhead.

No action required.

Table 18. LCD Message Troubleshooting (continued)

Displayed Message

Can User

Correct?

Explanation

Solution