ADMINISTRATOR GUIDE

PRI Board

Network Configuration

E1/T1 Interface Configuration

E1 CRC4

Used for most E1-PRI configurations.

On:

If set to On, the E1 CRC4 is enabled.

Off:

If set to Off, the E1 CRC4 is disabled. If your network

equipment does not support this feature, turn it Off.

T1 Cable Length

Specifies the cable length between the TANDBERG MPS and
the CSU for each of the PRI lines (only valid for T1 networks).
Possible values are:

Range1: 0 to 133 feet

Range2: 133 to 266 feet

Range3: 266 to 399 feet

Range4: 399 to 533 feet

Range5: 533 to 655 feet

This section configures each of the E1/T1 interfaces individu-
ally. There is one column for each interface (IF1, IF2,IF3, etc).
However, if PRI Trunk Groups is enabled, the number range
for PRI 1 will also apply for all the enabled PRI interfaces on
the same E1/T1 Interface Card.