Pri board, Pri board in slot 1-n (1:3) – TANDBERG Media Processing System MPS 200 User Manual
Page 88

D 13373.08
NOVEMBER 2007
MPS
TANDBERG
MPS
ADMINISTRATOR GUIDE
PRI Board
Network Configuration
PRI Board in Slot 1-n (1:3)
HLC
On:
Enables sending of HLC (High Level Compatibility) infor-
mation element in setup message (video calls only).
Off:
Disables sending of HLC information element in setup
message (video calls only), (Default: Off).
Parallel Dial
On:
Channels will be dialed and connected in parallel when
setting up a BONDING call (Default: On).
Off:
Channels will be dialed sequentially, which may in-
crease setup time.
Send Number
On:
The TANDBERG MPS will send its own number to the far
end. This is only useful when each conference have specified
a Dial In number (Default: On).
Off:
The TANDBERG MPS will not send its own number to
the far end. Please note that the network may still send your
number to the far end.
Send Complete
On:
The TANDBERG MPS will send the ISDN message infor-
mation element
Setup message. This is only required in a few countries.
Off:
The TANDBERG MPS will not send plete> (Default: Off). PRI Board Configuration Please ensure that Network Type is set to PRI for the correct ISDN cards in the PRI Network Configuration . ! Save - Press the Save button to save changes. 88 Introduction Quick Setup Using the MPS System Status Installation Gateway Configuration MCU Configuration Technical Descriptions Appendices Main System Configuration