Automatic Continuous Presence (CP) Layout Switching

When Conference Layout is set to Auto the following table de-
scribes the picture sent from the TANDBERG MPS.

The TANDBERG MPS allows for changing between any of these
modes during the conference.

TANDBERG Best Impression

TF

TANDBERG’s Best Impression

TF

feature consists of 3 parts:

Automatic Continuous Presence

(CP) layout switching

Automatic Continuous Presence

(CP) resolution switching

Enhanced video transcoding

Features

Video Features (1:2)

Layout Switching

No of video sites in conference Picture Mode used

1 or 2

Full Screen

3 -> 6

5 + 1 split

> 6

7 + 1 split

Automatic Continuous Presence (CP) Resolution Switching
Voice Switched Mode

In Voice Switched mode or when someone has the floor the TAND-
BERG MPS will send the same format as the one received if all
sites are capable of receiving it.
If one of the sites cannot receive the preferred video format (or if a
site asks for a video format not supported by the MCU), the MCU
will fallback according to the following table:

Voice Switched Mode

Preferred Video Format

Fallback Video Format

XGA

SVGA

SVGA

VGA

VGA

4CIF

4SIF

4CIF

4CIF

H.263 CIF

H.264 SIF

H.264 CIF

H.264 CIF

H.263 CIF

H.263 SIF

H.263 CIF

H.263 CIF

H.261 CIF

H.261 CIF

H.263 QCIF

H.263 QCIF

H.261 QCIF

Automatic Continuous Presence (CP) Resolution Switching
Continuous Presence Mode (CP)

In Continuous Presence mode the TANDBERG MPS administrator may set the conference up
for Motion, Sharpness or Auto:

Continuous Presence Mode

Video Format
Modes

CP Mode

Meeting Rate

MCU will transmit the highest possible
common video format according to:

MOTION

Any

Any

H.263 w288p -> H.264 CIF -> H.263 CIF ->
H.261 CIF -> H.263 QCIF -> H.261 QCIF

SHARPNESS

Any

Any

H.263 w576p -> H.263 4CIF -> H.264 CIF
-> H.263 CIF -> H.261 CIF -> H.263 QCIF
-> H.261 QCIF

AUTO (4:3)

Any

< 256 kbps

Same formats as for MOTION, excluding
w288p

AUTO (16:9)

Any

< 512 kbps

w288p

AUTO (4:3)

Any

=> 256 kbps

Same formats as for SHARPNESS, exclud-
ing w576p

AUTO (16:9)

Any

=> 512 kbps

w576p

TANDBERG Best Impression

TF

Automatic Continuous Presence (CP) Resolution Switching
DuoVideo

TF

/H.239/BFCP

DuoVideo

TF

/H.239/BFCP may be sent in both Continous Precence and Voice Switched

mode.

The TANDBERG MPS will transmit the same format as the one received if all the sites

are capable of receiving it.

The Video Format will fallback is as described for Voice Switched mode.