Chapter 4 Equipment List

Page 4- 8

NEAX2000 IPS

Request For Proposal (RFP) Reference Guide

NDA-24349 Issue 4

Line/Trunk (LT) Cards

The following table shows a summary of the Line/Trunk (LT) cards for NEAX 2000 IPS. The LT cards
may be installed in slot 00 to 11 of PIM 0-7, with the following conditions:

Line/Trunk (LT) Cards

Function

Name

Port

Remarks

PN-8LCAA

8

8L Analog Line Circuit
Message Waiting Control: 8 circuits
Momentary Open: 8 circuits
Loop Resistance: Max. 600ohms including
telephone set

PN-8LCS

8

8-Line Analog Station Card
Momentary Open: 8 circuits, Message
Waiting notification via Stutter Dial
Tone only. Loop Resistance: Max. 600
ohms
Note:

DM & DMR must use with

PN-4LCAA.

PN-4LCD-A

4

4L Analog Line Circuit with MW Lamp
control
Momentary Open: 4 Circuits
On-Board power (80V) is included.
Loop Resistance: Max. 600ohms including
telephone set

PN-AUCA 2

2L Analog Universal Trunk
2L Long Line Circuit with PFT
Loop resistance: max. 2500ohms (LLC)
Two reverse circuits is included
On Board power (-48V) is included

PN-4LCAA 4

4-Line Analog Station Card with built-in
Ring Generator. For use with NEAX
IPS DM and DMR only, Provides Line
Test function
“No Messaging Waiting Lamp” Utilizes
Stutter Dial Tone for MW notification.
Loop Resistance: Max 600 ohms

Analog Station

PN-4LLCB 4

4L Long Line Circuit
Works in either mode:
Long Line Station
Caller ID
Loop Resistance:
Max. 2500ohms including telephone set
PZ-PW122 is required.
Can not be used in IPS

DM

or IPS

DMR

ISDN Station

SPN-2ILCA 8

2-line ISDN Line Circuit Card.
• Provides a physical interface to ISDN
Terminals.
• Occupies eight time slots per one card.