beautypg.com

NEC NEAX NDA-24349 User Manual

Page 49

background image

Chapter 2 System Architecture

NEAX2000 IPS

Request For Proposal (RFP) Reference Guide

Page 2-15

NDA-24349 Issue 4

System Power Supply and cooling fan

AC/DC Power Supply


The AC/DC Power Card is mounted in the rear side of each MODULAR CHASSIS. The AC/DC Power
card provides power to all circuit cards, which are resided in the MODULAR CHASSIS.

AC power requirements are as follows:

Input Voltage: 85 to 264VAC, 50/60 Hz (Auto sensing 100V/200V selection)

AC/DC Power Card

Description

Qty

Remarks

PZ-PW131

1 per MODULAR CHASSIS

AC/DC Power Supply
Output:+5 V, 5.5A, -27 V, 3A


Back-up Power

UPS or battery backup (with external battery) is available for backup power for AC power failure.
In case of battery backup, sealed type battery should be used. The open type battery is not
available because of AC/DC power specifications.

Cooling FAN

The cooling FAN is mounted at the right side of each MODULAR CHASSIS. The FAN should be
replaced every 4 years in order to ensure the cooling system.

Cooling FAN

Description

Qty

Remarks

109P0624H

7D09 FAN

1/MODULAR CHASSIS