NEC NEAX NDA-24349 User Manual
Page 49
Chapter 2 System Architecture
NEAX2000 IPS
Request For Proposal (RFP) Reference Guide
Page 2-15
NDA-24349 Issue 4
System Power Supply and cooling fan
AC/DC Power Supply
The AC/DC Power Card is mounted in the rear side of each MODULAR CHASSIS. The AC/DC Power
card provides power to all circuit cards, which are resided in the MODULAR CHASSIS.
AC power requirements are as follows:
Input Voltage: 85 to 264VAC, 50/60 Hz (Auto sensing 100V/200V selection)
AC/DC Power Card
Description
Qty
Remarks
PZ-PW131
1 per MODULAR CHASSIS
AC/DC Power Supply
Output:+5 V, 5.5A, -27 V, 3A
Back-up Power
UPS or battery backup (with external battery) is available for backup power for AC power failure.
In case of battery backup, sealed type battery should be used. The open type battery is not
available because of AC/DC power specifications.
Cooling FAN
The cooling FAN is mounted at the right side of each MODULAR CHASSIS. The FAN should be
replaced every 4 years in order to ensure the cooling system.
Cooling FAN
Description
Qty
Remarks
109P0624H
7D09 FAN
1/MODULAR CHASSIS