beautypg.com

NEC NEAX NDA-24349 User Manual

Page 213

background image

Chapter 10 System Input/Output (I/O) Interfaces

NEAX 2000 IPS

Request for Proposal (RFP) Reference Guide

Page 10-5

NDA-24349, Issue 4

Note: In case of built-in SMDR, if the station number is a 7- or 8- digit number, the upper one or
two digits are sent as Calling office Number and the last six digits are sent as Calling Number in
the call record format.

b. SMDR with AP00

o

AP00 without expansion memory (standard): up to 1600 calls (if central office feature is used,
up to 800 calls)

o

AP00 with expansion memory (optional): up to 27000 calls (if central office feature is used,
up to 26000 calls)

o

When a call is completed, the record is sent to the output device and is removed from
memory.

o

If the amount of calls exceed the SMDR memory, those overflow calls will not be recorded.

ƒ

The built-in SMDR cannot be provided when AP00 is mounted.

ƒ

Account Codes, Forced Account Codes, Authorization Codes and DISA Codes on Tandem
connections (SMDR with AP00 only) are reported in the applicable call record.

ƒ

SMDR with AP00 provides a record of incoming Tie Line tandem calls where another trunk is dial
accessed.

ƒ

For details of SMDR format, data stream, memory buffer, etc., refer to the Installation Procedure
Manual/Feature Programming Manual.

ƒ

Up to 16 digits of the calling subscriber’s number for Automatic Number Identification (ANI) and
CPN (IS-DN) can be recorded in the SMDR by system programming.

Data Transmission Sequence for Ethernet Interface

Establishing a connection, outputting billing Information, and releasing a connection are performed
between the PBX and the SMDR terminal in the following timings.

ƒ

Timing to Establish a Connection

o

A connection is established when a connection request is received from the SMDR

terminal.

ƒ

Timing to Output Billing Information

o

Billing information is output when a polling request is received from the SMDR terminal

connected to LAN.

ƒ

Timing to Release the Connection

o

The connection is released when the SMDR terminal does not receive data from the
PBX in a predetermined time interval. Also the connection is released when the PBX
receives connection release text from the SMDR terminal or does not receive data from
the SMDR terminal within a given time interval

.