System specifications – NEC NEAX NDA-24349 User Manual
Page 68
![background image](/manuals/193093/68/background.png)
Chapter 3 System Highlights
Page 3- 16
NEAX2000 IPS
Request For Proposal (RFP) Reference Guide
NDA-24349 Issue 4
System Specifications
AC Power Requirements
Description
Specifications
AC Input Voltage
90 to 132Vac or 180 to 264Vac; 47 to 64Hz
AC Input Current
3.5A(at 100V), 2.0A(at 200V)
AC Power Consumption / Thermal Output (Maximum)
AC Power Consumption (KVA)
Thermal Output (BTU)
Description
100V
200V
100V
200V
1-PIM 0.35
0.40
1,195
1,365
2-PIM 0.70
0.80
2,389
2,730
3-PIM 1.05
1.20
3,584
4,096
4-PIM 1.40
1.60
4,778
5,461
5-PIM 1.75
2.00
5,973
6,826
6-PIM 2.10
2.40
7,167
8,191
7-PIM 2.45
2.80
8,362
9,556
8-PIM 2.80
3.20
9,556
10,922
Battery Requirements
Description
Specifications
Max. Battery Capacity
260AH per 4 PIM (65AH (12V) x 8)
DC Input Voltage for Battery
-24V
Built-in Battery Requirements
3.4AH (12V) x 2 (approx. 30min. backup)
Physical Size of Built-in Battery
(one 12V battery)
133(W) x 60(H) x 67(D) mm
Operating Environment
Description
Specifications
Ambient Temperature
32
0
F to 104
0
F (0
0
C to 40
0
C)
Relative Humidity
Max. 90% (non-condensing)