Chapter 5 Station Equipment
Page 5- 28
NEAX2000 IPS
Request For Proposal (RFP) Reference Guide
NDA-24349 Issue 4
D
term
Series E Line Conditions
Loop Resistance and Distance (Long Loop circuit built-in)
Terminal
Maximum
Loop Resistance ( )
Cable Length
(24 AWG Cable)
(Without
ACA Unit)
Cable Length
(24 AWG Cable)
(With ACA Unit)
DTP-8-1 TEL
35
1000 ft. (304 m)
4000 ft. (1219 m)
DTP-8D-1 TEL
35
1000 ft. (304 m)
4000 ft. (1219 m)
DTP-16D-1 TEL
26
650 ft. (198 m)
4000 ft. (1219 m)
DTP-32D-1 TEL
21
650 ft. (198 m)
4000 ft. (1219 m)
4DLC
DCU-60-1 Console
N/A
N/A
1000 ft. (304 m)
DTP-8-1 TEL
35
1000 ft. (304 m)
1000 ft. (304 m)
DTP-8D-1 TEL
35
1000 ft. (304 m)
1000 ft. (304 m)
DTP-16D-1 TEL
26
650 ft. (198 m)
1000 ft. (304 m)
DTP-32D-1 TEL
21
650 ft. (198 m)
1000 ft. (304 m)
8DLC
DCU-60-1 Console
N/A
N/A
1000 ft. (304 m)
DTP-8-1 TEL
35
2800 ft. (853 m)
4000 ft. (1219 m)
DTP-8D-1 TEL
35
2800 ft. (853 m)
4000 ft. (1219 m)
DTP-16D-1 TEL
26
2800 ft. (853 m)
4000 ft. (1219 m)
DTP-32D-1 TEL
21
2800 ft. (853 m)
4000 ft. (1219 m)
2DLCB/N
DCU-60-1 Console
N/A
N/A
2800 ft. (853 m)