beautypg.com

IBM SG24-4817-00 User Manual

Page 291

background image

This soft copy for use by IBM employees only.

chassisChange TRAP-TYPE

ENTERPRISE

node

DESCRIPTION

A chassisChange trap is used to indicate that a configuration

change has occurred.

The actual variables that changed

are included in the variables section of the PDU.

::= 107

chassisModuleDown TRAP-TYPE

ENTERPRISE

node

DESCRIPTION

A chassisModuleDown trap indicates that management communications

with a slot has been
broken.

This event usually occurs when a module has been

physically removed from the concentrator.

However, it

is possible for this event to occur when the particular
module fails.

::= 116

chassisModuleUp TRAP-TYPE

ENTERPRISE

node

DESCRIPTION

A chassisModuleUp trap indicates that management communications

with a slot has been
established.

This event usually occurs when a module has

physically been inserted into the concentrator.

The

variable chipModType indicates the module type inserted.

::= 117

END

Appendix E.

IBM ATM Campus Switch Private MIBs

275