DESCRIPTION

The VPI value for this connection.

::= { vpXConnectEntry 2 }

vpXOutIndex OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The interface number for this ATM port.

::= { vpXConnectEntry 3 }

vpXOutVpi OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The VPI value for this connection.

::= { vpXConnectEntry 4 }

vpXType

OBJECT-TYPE

SYNTAX

INTEGER { unicast (1),

multicast (2)

}

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

Whether this cross-connection is part of a unicast or a
multicast connection.

::= { vpXConnectEntry 5 }

vpXDirection OBJECT-TYPE

SYNTAX

INTEGER { upstream (1),

downstream (2)

}

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

Whether this entry identifies this cross-connection in
the upstream or downstream flow, as seen from the root.

Downstream means that the connection was set up from the
in parameters (interface, VPI) to the out parameters
(interface, VPI).

Upstream means that the connection was set up from the
out parameters (interface, VPI) to the in parameters
(interface, VPI).

As a result, any cross-connection is modeled in this table
as two entries, depending on whether it is seen in the
up or down stream.

::= { vpXConnectEntry 6 }

-- Neighbor Devices

neighbor OBJECT IDENTIFIER ::= { node 5 }

220