The result of the latest file transfer.
When one of the TFTP variables is modified, this
variable is reset to not-initialized.
When a configuration file is downloaded, the content of
the configuration file is checked. If the file is valid
and if a reset is mandatory then the atm subsystem is
reset automatically.
If the configuration file is not valid or if a reset
is not required, the following values are returned in
transferResult:

- config-unreadable-version: the control point

does not support the version of configuration file.
This configuration file has probably been built
by a further version of control point.

- config-file-empty: the configuration file is not valid
- config-impossible: the configuration file cannot

be applied (internal error, or file corrupted)

- config-internal-error: internal error detected while

checking the configuration file.

- config-applied-ok: the configuration file is valid

and a reset is not mandatory.

::= { tftp 7 }

-- Service

service OBJECT IDENTIFIER ::= { node 7 }

-- Traces

traces OBJECT IDENTIFIER ::= { service 1 }

sysTrace OBJECT-TYPE

SYNTAX

INTEGER { on (1),

off (2)

}

ACCESS

read-write

STATUS

mandatory

DESCRIPTION

When on, the hub general trace facility is started.
Messages are stored in the hub in a file that can be
retrieved through TFTP.
When off, the general trace facility is stopped and
messages are no longer logged.

::= { traces 1 }

trsTrace

OBJECT-TYPE

SYNTAX

INTEGER { on (1),

off (2)

}

ACCESS

read-write

STATUS

mandatory

DESCRIPTION

When on, the Topology and Routing Selection trace is
started.
Messages are stored in the hub in a file that can be
retrieved through TFTP.
When off, the control point trace facility is stopped and
messages are no longer logged.

::= { traces 2 }