beautypg.com

IBM SG24-4817-00 User Manual

Page 284

background image

This soft copy for use by IBM employees only.

ocPowerOutputWattageAvailable OBJECT-TYPE

SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION

In hundredths of a Watt (1/100 Watt), the wattage

available to power-up modules.

If power fault-tolerant

mode is enabled (when it was previously disabled), this
object

s value is decreased by the amount of power reserved

for the voltage line.

If power fault-tolerant mode is

disabled (when it was previously enabled), this object

s

value is increased by the amount of power that is returned
to the available power budget for the voltage line.

::= { ocPowerOutputEntry 5 }

ocPowerOutputUnmanagedWattageAlloc OBJECT-TYPE

SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION

In hundredths of a Watt (1/100 Watt), the wattage

reserved for modules that are not power-manageable.
This value 0 is always returned.

::= { ocPowerOutputEntry 6 }

--
-- Module power configuration
--
ocPowerSlotTable OBJECT-TYPE

SYNTAX SEQUENCE OF OcPowerSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION

A table that contains power management information

for each non-empty, payload slot in the hub.

Note

that for multi-slot IBM 8260 modules, there is one point
of power management contact and control.

Hence, only

the leftmost slot is represented in this table.

::= { ocPower 3

}

ocPowerSlotEntry OBJECT-TYPE

SYNTAX OcPowerSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION

A list of power management information for each

payload slot in the hub containing an 8260 module.

INDEX { ocPowerSlotIndex }
::= { ocPowerSlotTable 1 }

OcPowerSlotEntry ::=

SEQUENCE {

ocPowerSlotIndex

INTEGER,

ocPowerSlotClass

INTEGER,

ocPowerSlotAdminStatus

INTEGER,

268

ATM Workgroup Solutions: Implementing the 8285 ATM Switch