ACCESS

not-accessible

STATUS

mandatory

DESCRIPTION

This table contains the cross-connections set-up in
the switch for all existing VCL-based PVCs and SVCs.

::= { connections 1}

vcXConnectEntry OBJECT-TYPE

SYNTAX

VcXConnectEntry

ACCESS

not-accessible

STATUS

mandatory

DESCRIPTION

Entries of vcXConnectTable.

INDEX { vcXInIndex ,

vcXInVpi,
vcXInVci,
vcXOutIndex,
vcXOutVpi,
vcXOutVci }

::= { vcXConnectTable 1 }

VcXConnectEntry ::= SEQUENCE {

vcXInIndex

INTEGER,

vcXInVpi

INTEGER,

vcXInVci

INTEGER,

vcXOutIndex

INTEGER,

vcXOutVpi

INTEGER,

vcXOutVci

INTEGER,

vcXType

INTEGER,

vcXDirection

INTEGER

}

vcXInIndex OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The interface number for this ATM port.

::= { vcXConnectEntry 1 }

vcXInVpi OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The VPI value for this connection.

::= { vcXConnectEntry 2 }

vcXInVci OBJECT-TYPE

SYNTAX

INTEGER

ACCESS

read-only

Appendix E.

IBM ATM Campus Switch Private MIBs