IBM SG24-4817-00 User Manual
Page 136

This soft copy for use by IBM employees only.
8285> save all
1
8285> swap microcode
You are about to change operational microcode version and reset the hub.
The saved hub configuration may be lost..
Are you sure ? (Y/N) Y
Migration allowed; checking for needed FPGA swaps
Some SWAP FPGA commands will be executed now...
Generated command: SWAP FPGA 1 ...
2
Press Enter
.
.
.
(system reboots)
.
.
.
8285> save all
1
8285> swap fpga_picocode 2
3
You are about to change operational FPGA version..
Are you sure ? (Y/N) Y
Processing slot
2 ... Swap completed.
2
Note:
1
Save configuration changes before starting.
2 SWAP FPGA
message will be generated for each module being
upgraded.
3 SWAP FPGA_PICOCODE
slot command entered to swap microcode
levels on the module in slot 2.
Table 31. Swap Errors and Suggested Fixes
Symptom
Possible Cause
Suggested Actions
Failure.
P r o m p t =
″ > >
nnnn
> >
″.
The 8285 ATM Control
Point was unable to find
FPGA code that was
valid with its
operational code, and
has reverted to
maintenance mode.
You must restore the
8285s operational code
and configuration.
•
Use the SWAP
ACTIVE command to
restore the previous
operational
microcode.
•
Use the BOOT
command to restart
the system.
•
Re-enter your
configuration
information.
•
Re-enter your TFTP
configuration
information.
•
Repeat the
download and swap
process.
120
ATM Workgroup Solutions: Implementing the 8285 ATM Switch