beautypg.com

IBM SG24-4817-00 User Manual

Page 251

background image

This soft copy for use by IBM employees only.

One of the Q2931 end point reference values used by this
SVC.
In a unicast SVC, there is only one entry for this SVC in
the table.
In a multicast SVC, there is one entry per party.

::= { atmSvcEntry 5 }

atmSvcCallingNumber OBJECT-TYPE

SYNTAX

AtmAddress

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The calling number carried in the calling party number
information element of the call set-up message.

::= { atmSvcEntry 6 }

atmSvcCalledNumber OBJECT-TYPE

SYNTAX

AtmAddress

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The called number carried in the called party number
information element of the call set-up message.

::= { atmSvcEntry 7 }

atmSvcClear OBJECT-TYPE

SYNTAX

INTEGER {

active (1),
clear (2)

}

ACCESS

read-write

STATUS

mandatory

DESCRIPTION

This variable allows a network manager to clear this
SVC.
When this SVC is cleared (either by the manager using
this variable or by one of the parties), the entry is
deleted from this table and another entry is created
in the atmSvcClearTable.

::= { atmSvcEntry 8}

atmSvcCreationTime OBJECT-TYPE

SYNTAX

DateAndTime

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The date and time this call was placed.

::= { atmSvcEntry 9 }

atmSvcVpi

OBJECT-TYPE

SYNTAX

INTEGER (0..255)

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The VPI value used by this SVC for this interface.

::= { atmSvcEntry 10}

Appendix E.

IBM ATM Campus Switch Private MIBs

235