SYNTAX
INTEGER {
isolated (1),
attached (2)
}
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
The actual state of the slot connection to the switch.
When the administrative state is set to ISOLATE, the
operational state becomes ISOLATED.
When the operational state is set to ATTACH, the operational
state may become either ATTACHED or ISOLATED depending on
the hardware current status of the slot.
″
::= { switchEntry 3 }
-- ATM modules
moduleTable
OBJECT-TYPE
SYNTAX
SEQUENCE OF ModuleEntry
ACCESS
not-accessible
STATUS
mandatory
DESCRIPTION
″
This table provides the list of ATM modules in the hub.
″
::= { physical 2}
moduleEntry OBJECT-TYPE
SYNTAX
ModuleEntry
ACCESS
not-accessible
STATUS
mandatory
DESCRIPTION
″
Entries of moduleTable.
″
INDEX { moduleSlotIndex }
::= { moduleTable 1 }
ModuleEntry ::= SEQUENCE {
moduleSlotIndex
INTEGER,
moduleType
INTEGER,
moduleDescription
DisplayString,
moduleSerialNumber
DisplayString,
moduleSoftwareVersion
DisplayString,
moduleHardwareVersion
INTEGER,
moduleAdminState
INTEGER,
moduleOperState
INTEGER,
moduleErrors
Counter,
moduleMaxVpc
INTEGER,
moduleUsedVpc
INTEGER,