beautypg.com

IBM SG24-4817-00 User Manual

Page 281

background image

This soft copy for use by IBM employees only.

slot/subslot is unoccupied, the timestamp indicates
the time that the module was removed.

If no module

has occupied this slot/subslot since the last
restart of the agent, the value of ssTimeLastChanged
for this entry is zero.

::= { ssLastChangedEntry 3 }

ssTimeLastChanged OBJECT-TYPE

SYNTAX

TimeTicks

ACCESS

read-only

STATUS

mandatory

DESCRIPTION

The value of SysUpTime at the time that the

last change was detected to any of the information
included in the summary table entry for this slot
and subslot.

A change in the value of this object

signals the management station to re-get the
corresponding summary information.

::= { ssLastChangedEntry 4 }

ssLastChangedSummary OBJECT-TYPE

SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION

This object contains the value of ssTimeLastChanged for

each slot/subslot in the concentrator. The first two
octets contain the version of this object. The data
following the version begins with the first slot and
all of its sub-slots before continuing with the next slot.

::= { staticSummary 3 }

--
-- IBM 8260 Power Group
--
-- This group is used for managing the
-- power in the IBM 8260 hub.

--
-- Hub power mode
--
ocPowerModeAdminStatus OBJECT-TYPE

SYNTAX INTEGER {

fault-tolerant(1),
not-fault-tolerant(2)
}

ACCESS read-write
STATUS mandatory
DESCRIPTION

The current desired state of hub power fault-tolerant

mode.

Setting this object to fault-tolerant(1) will

reserve one power supply

s worth of power from the power

budget for fault-tolerant operation, provided sufficient
power is available.

Setting this object to

not-fault-tolerant(2) returns the reserved power to the
power budget.

::= { ocPowerControl 1 }

Appendix E.

IBM ATM Campus Switch Private MIBs

265