DESCRIPTION
″
A PVC failure trap is sent when a PVC becomes inoperational.
″
::= 4
-- node.5 intentionnally left unused
callLoggingOverflow TRAP-TYPE
ENTERPRISE node
DESCRIPTION
″
A callLoggingOverflow trap is sent when the call logging table
is about to wrap.
″
::= 6
moduleInstalled TRAP-TYPE
ENTERPRISE node
VARIABLES { moduleSlotIndex }
DESCRIPTION
″
An ATM module has been detected in the hub.
″
::= 7
moduleRemoved TRAP-TYPE
ENTERPRISE node
VARIABLES { moduleSlotIndex }
DESCRIPTION
″
An ATM module is no longer detected in the hub.
″
::= 8
lesMaxClientsReached TRAP-TYPE
ENTERPRISE node
VARIABLES { lesIndex }
DESCRIPTION
″
The maximum number of lan emulation
clients has been connected to the given lan emulation
server.
″
::= 9
lesMaxClientsThresholdDown TRAP-TYPE
ENTERPRISE node
VARIABLES { lesIndex }
DESCRIPTION
″
The number of operational clients of the given emulated
lan is now equal to lesMaxNumberOfClients - 10.
This trap is sent only if
the
trap lesMaxClientsReached has been sent previously.
lesIndex is the index of the lesConfTable defined above
″
::= 10
-- Expansion Description
expansion OBJECT IDENTIFIER ::= { atmSw 4 }
expansionHardwareVersion OBJECT-TYPE
SYNTAX
DisplayString
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
The Part Number (P/N) and Engineering Change (EC) level
and Plant Location for this module.
″
::= { expansion 1 }
Appendix E.