ocPowerOutputWattageAvailable
Gauge,
ocPowerOutputUnmanagedWattageAlloc
Gauge
}
ocPowerOutputType OBJECT-TYPE
SYNTAX INTEGER {
plusFiveVolt(1),
-- + 5 Volt
minusFiveVolt(2),
-- - 5 Volt
plusTwelveVolt(3),
-- +12 Volt
minusTwelveVolt(4),
-- -12 Volt
plusTwoVolt(5)
-- + 2 Volt
}
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
Identifies the power (voltage) line type for which this
entry contains power budget information.
″
::= { ocPowerOutputEntry 1 }
ocPowerOutputVoltageLevel OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
″
In millivolts (1/1000 Volt), the actual voltage level
for this voltage type as sensed on the backplane.
This
voltage is supplied by all operational power supplies.
″
::= { ocPowerOutputEntry 2 }
ocPowerOutputWattageCapacity OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
″
In hundredths of a Watt (1/100 Watt), the maximum
wattage for the voltage line that is output by all
operational power supplies combined.
″
::= { ocPowerOutputEntry 3 }
ocPowerOutputWattageConsumed OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
″
In hundredths of a Watt (1/100 Watt), the wattage
consumed by all hub modules.
For a given voltage line,
this object
′
s value is the sum total of the power
consumed by the hub itself, the Controller Modules
and all power-enabled slots containing IBM 8260 modules.
If power fault-tolerant mode is enabled (when it was
previously disabled), this object
′
s value is increased
by the amount of power reserved for the voltage line.
If power fault-tolerant mode is disabled (when it was
previously enabled), this object
′
s value is decreased
by the amount of power that is returned to the available
power budget for the voltage line.
″
::= { ocPowerOutputEntry 4 }