beautypg.com

IBM SG24-4817-00 User Manual

Page 274

background image

This soft copy for use by IBM employees only.

SYNTAX INTEGER {

one(1),

-- lowest

two(2),
three(3),
four(4),
five(5),
six(6),
seven(7),
eight(8),
nine(9),
ten(10),

-- highest

never(11)
}

ACCESS read-only
STATUS mandatory
DESCRIPTION

The mastership priority of this agent.

Ten is the

highest and one is the lowest.

Never means will not

be able become master. MasterPriority is only used
when an election occurs. Mastership is not pre-emptive.

::= { agentsEntry 5 }

ocAgentsSubSlot OBJECT-TYPE

SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION

The subslot index for this agent.

For agents not located

in the IBM 8260 system, this object will always
return 1 for this object value.

::= { agentsEntry 6 }

-- The conc Group:

-- This group is mandatory for all devices that are acting as a concentrator
-- master.
--
-- The conc group contains information and control relative to
-- the concentrator.
--

concType OBJECT-TYPE

SYNTAX INTEGER {

hub-8260-017-A(6),

-- 17-slot with ring backplane

hub-8260-010-A(10)

-- 10-slot with ring backplane

}
ACCESS read-only
STATUS mandatory
DESCRIPTION

This object identifies the type of concentrator represented

by this agent.

::= { conc 1 }

concReset OBJECT-TYPE

SYNTAX INTEGER {

noReset(1),
reset(2)
}

258

ATM Workgroup Solutions: Implementing the 8285 ATM Switch