IBM SG24-4817-00 User Manual
Page 258
![background image](/manuals/126122/258/background.png)
This soft copy for use by IBM employees only.
STATUS
mandatory
DESCRIPTION
″
MaxCC as defined in the Q.2110 Specification.
This is the maximum value for the state variable
VT(CC), corresponding to the maximum number of
transmissions of a BGN, END, ER or RS PDU.
″
::= { atmSaalConfEntry 10 }
atmSaalMaxPD
OBJECT-TYPE
SYNTAX
INTEGER
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
MaxPD as defined in the Q.2110 Specification.
This is the maximum iacceptable value for the state
variable VT(PD) before sending a POLL PDU and
resetting VT(PD) to zero.
This parameter is an upper limit for counter VT(PD)
that sends a POLL PDU after every (MaxPD) SD PDUs.
″
::= { atmSaalConfEntry 11}
atmSaalMaxStat
OBJECT-TYPE
SYNTAX
INTEGER
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
MaxSTAT as defined in the Q.2110 Specification.
This is the maximum number of list elements
placed in a STAT PDU.
″
::= { atmSaalConfEntry 12}
-- This table defines the SAAL statistics.
atmSaalStatsTable
OBJECT-TYPE
SYNTAX
SEQUENCE OF AtmSaalStatsEntry
ACCESS
not-accessible
STATUS
mandatory
DESCRIPTION
″
This table contains statistics for the SAAL protocol,
for outgoing calls only.
″
::= { atmSaal 2 }
atmSaalStatsEntry OBJECT-TYPE
SYNTAX
AtmSaalStatsEntry
ACCESS
not-accessible
STATUS
mandatory
DESCRIPTION
″
Entries of atmSaalConfTable. Each entry corresponds to a pair
of ATM interface, signalling channel.
A signalling channel is uniquely defined on each interface
by the VPI and VCI values allocated to it.
″
INDEX { atmSaalStatsIndex,
atmSaalStatsSiVpi,
atmSaalStatsSiVci }
::= { atmSaalStatsTable 1 }
AtmSaalStatsEntry ::= SEQUENCE {
atmSaalStatsIndex
INTEGER,
242
ATM Workgroup Solutions: Implementing the 8285 ATM Switch