IBM SG24-4817-00 User Manual
Page 253

This soft copy for use by IBM employees only.
AtmSvcLogEntry ::= SEQUENCE {
atmSvcLogIndex
INTEGER,
atmSvcLogInterfaceIndex
INTEGER,
atmSvcLogCallingNumber
AtmAddress,
atmSvcLogCalledNumber
AtmAddress,
atmSvcLogCreationTime
DateAndTime,
atmSvcLogTime
DateAndTime,
atmSvcLogClearCause
INTEGER,
atmSvcLogForwardQOS
INTEGER,
atmSvcLogBackwardQOS
INTEGER,
atmSvcLogForwardBW
INTEGER,
atmSvcLogBackwardBW
INTEGER }
atmSvcLogIndex OBJECT-TYPE
SYNTAX
INTEGER
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
An identification value for this entry, assigned by the
local SNMP agent.
This value is assigned for each new SVC call or
add-party request.
This index is allocated in a decreasing order, so that
a get-next request on the table allows to retrieve the
latest calls first.
″
::= { atmSvcLogEntry 1 }
atmSvcLogInterfaceIndex OBJECT-TYPE
SYNTAX
INTEGER
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
The ifIndex value of the ATM interface used by this
SVC.
″
::= { atmSvcLogEntry 2 }
atmSvcLogCallingNumber OBJECT-TYPE
SYNTAX
AtmAddress
ACCESS
read-only
STATUS
mandatory
DESCRIPTION
″
The calling number carried in the calling party number
information element of the call set-up message.
″
::= { atmSvcLogEntry 3 }
atmSvcLogCalledNumber OBJECT-TYPE
SYNTAX
AtmAddress
ACCESS
read-only
Appendix E.
IBM ATM Campus Switch Private MIBs
237