Syntax show rmon - list the specific RMON data as defined by the group

type

Chapter 19 – Miscellaneous
Commands

Syntax alarm – enter the alarm configuration mode

Syntax
add event= - enables alarm action in response to the specified event ID

Syntax
period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be

needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds


Syntax
del event= - disables alarm action in response to the specified event ID

Syntax
alarm - globally enables or disables the alarm action

Syntax show alarm - displays the current status of Alarm system


Syntax
smtp – configure the SNMP alerts to be sent via email

Syntax show smtp -

config

– displays the current SMTP global settings and

recipients

displays the currently configured recipients of email alerts


Syntax add id=<1-5> email= [traps=]

[events=] [ip=] [port=<1-65535>]

id – [mandatory] the recipient ID - range from 1 to 5. MNS-6K allows a maximum of 5

recipients


email – [mandatory] email address of the recipient

traps – [optional] this is the trap filter. If value is “all”, all traps of any type will be sent to

this recipient. If value is none, no traps are sent to this recipient. Value can also be
a combination of ‘S’ (SNMP), ‘R’ (RMON) and ‘E’ (ENTERPRISE). For example,
trap=SR means that SNMP and RMON traps will be sent via email to the recipient.
If this option is not defined, the recipient will have a default value of “all”


events – [optional] this is the event filter. Value can be “all” - all event severity types will

be sent to recipient, “none” - no event will be sent to recipient or a combination of
‘I’ (informational), ‘A’ (activity), ‘C’ (critical), ‘F’ (fatal) and ‘D’ (debug). With

275