GarrettCom Magnum MNS-6K User Manual
Page 260
M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E
Syntax set serial [baud=
[stop=<1|1.5|2>] [flowctrl=
Syntax snmp – enter the snmp configuration mode
Syntax setvar [sysname|syscontact|syslocation]=
location information
Syntax set timezone GMT=[+ or -] hour=<0-14> min=<0-59> - sets the timezone
Syntax set date year=<2001-2035> month=<1-12> day=<1-31>
[format=
date is displayed
Syntax
set time hour=<0-23> min=<0-59> sec=<0-59> [zone=GMT[+/-]hh:mm] – sets the
time (as well as the timezone)
Syntax
set timeformat format=<12|24> - sets the display time in the 12/24 hour mode
Syntax
set daylight country=< country name> - sets the daylight saving time
Syntax setsntp server =
Syntax sync [hour=<0-24>] [min=<0-59>] – setup the frequency at which the SNTP server is queried
Syntax sntp [enable|disable] – enables or disables the SNTP services
Syntax saveconf mode=
configuration on the network using tftp, ftp or serial protocols
Syntax loadconf mode=
saved configuration from the network using tftp, ftp or serial protocols
Syntax kill config [save=module_name] – resets the system configuration. The module_name option does not
reset the specific module parameters. The modules are system, event, port, bridge, stp, ps, mirror, sntp, vlan, gvrp
and snmp
Syntax show session – display telnet sessions active on the switch
Syntax kill session id=
Syntax set ftp mode=
Syntax show ftp- display the current ftp operation mode