beautypg.com

GarrettCom Magnum MNS-6K User Manual

Page 206

background image

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set-qi interval= - The IGMP querier router periodically sends general host-query

messages. These messages are sent to ask for group membership information. This is sent to the all-
system multicast group address, 224.0.0.1. The default value is 125 seconds. The valid range can be
from 60 to 127 seconds.

Syntax set-qri interval= - The query response interval is the maximum amount of time that

can elapse between when the querier router sends a host-query message and when it receives a response
from a host. The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions
apply to the maximum value because of an internal calculation that is dependent on the value of the
Query Interval.

Magnum6K25#

igmp


Magnum6K25(igmp)##

set-port port=10-12 mode=forward


Port mode is set.

Magnum6K25(igmp)##

set-port port=14-16 mode=block


Port mode is set.

Magnum6K25(igmp)##

show-port

-----------------------------------
Port | Mode
-----------------------------------
09

Auto

10

Forwarding

11

Forwarding

12

Forwarding

13

Auto

14

Blocking

15

Blocking

16

Blocking


Magnum6K25(igmp)##

show-router


RouterIp PortNo Timer
--------------------------------------
10.21.1.250 9 25

Magnum6K25(igmp)##

set-leave enable


IGMP immediate leave status is enabled

Magnum6K25(igmp)##

show igmp


IGMP State

: Enabled

ImmediateLeave

: Enabled

Querier

: Enabled

205