GarrettCom Magnum MNS-6K User Manual
Page 238

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E
Syntax period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be
needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds
Syntax del event=
Syntax alarm
Syntax show alarm - displays the current status of Alarm system
Magnum6K25#
alarm
Magnum6K25(alarm)##
add event=2
Alarm Event(s) Added: 2
Magnum6K25(alarm)##
add event=1-5
Event 2 is Already Enabled.
Alarm Event(s) Added: 1, 3, 4, 5
Magnum6K25(alarm)##
add event=6,8
Alarm Event(s) Added: 6, 8
Magnum6K25(alarm)##
add event=all
Event 1 is Already Enabled.
Event 2 is Already Enabled.
Event 3 is Already Enabled.
Event 4 is Already Enabled.
Event 5 is Already Enabled.
Event 6 is Already Enabled.
Event 8 is Already Enabled.
Alarm Event(s) Added: 7, 9, 10, 11, 12
Magnum6K25(alarm)##
del event=2
Alarm Event(s) Deleted: 2
Magnum6K25(alarm)##
period time=5
Relay closure Time Set.
Magnum6K25(alarm)##
show alarm
Alarm Events Configuration
--------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 5 Seconds
EventId Description
Mode
1 S-RING OPEN
SUSTAINED
2 Cold Start
NOT ENABLED
3 Warm Start
MOMENTARY
4 Link Up
MOMENTARY
237