Syntax period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be 
needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds
 
Syntax del event=
 
Syntax alarm 
 
Syntax show alarm - displays the current status of Alarm system 
 
Magnum6K25#
alarm
 
Magnum6K25(alarm)## 
add event=2
Alarm Event(s) Added: 2 
 
Magnum6K25(alarm)## 
add event=1-5
Event 2 is Already Enabled. 
Alarm Event(s) Added: 1, 3, 4, 5 
 
Magnum6K25(alarm)## 
add event=6,8
Alarm Event(s) Added: 6, 8 
 
Magnum6K25(alarm)## 
add event=all
Event 1 is Already Enabled. 
Event 2 is Already Enabled. 
Event 3 is Already Enabled. 
Event 4 is Already Enabled. 
Event 5 is Already Enabled. 
Event 6 is Already Enabled. 
Event 8 is Already Enabled. 
Alarm Event(s) Added: 7, 9, 10, 11, 12 
 
Magnum6K25(alarm)## 
del event=2
Alarm Event(s) Deleted: 2 
 
Magnum6K25(alarm)## 
period time=5
Relay closure Time Set. 
 
Magnum6K25(alarm)## 
show alarm
Alarm Events Configuration 
-------------------------- 
 
 Alarm Status: DISABLED 
 Relay Closure Time Period: 5 Seconds 
 
 
EventId Description
Mode
 
 1 S-RING OPEN 
SUSTAINED
2 Cold Start
NOT ENABLED
3 Warm Start
MOMENTARY
4 Link Up
MOMENTARY