Configuring s-ring, Igure, Activating s-ring on the switch – GarrettCom Magnum MNS-6K User Manual
Page 160
M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E
Configuring S-Ring
S-Ring is a licensed software feature from GarrettCom Inc. Before using the S-Ring
capabilities; authorize the use of the software with the license key. To obtain the license key,
please contact GarrettCom Inc. Sales (for purchasing the S-Ring feature) or Technical
Support (to obtain the 12 character key.) If the S-Ring capability was purchased along with
the switch, the software license code will be included with the switch.
Syntax authorize
to use the “save” command to save the key
In the example below – STP is used to show how S-Ring is setup. S-Ring
will also work with RSTP. If RSTP is used, GarrettCom Inc. recommends
using RS-Ring instead.
Magnum6K25#
authorize s-ring key=abc123456789
S-RING Module Successfully Authorized
Please Save Configuration.
Magnum6K25#
save
Saving current configuration
Configuration saved
Saving current event logs
Event logs saved
Magnum 6K25#
reboot
Proceed on rebooting the switch? [ 'Y' or 'N' ]
Y
Do you wish to save current configuration? [ 'Y' or 'N' ]
Y
Saving current configuration
Configuration saved
Rebooting now...
F
IGURE
87
– Activating S-Ring on the switch
Since S-Ring uses RSTP/STP, STP has to be activated and enabled. Please refer to the
Chapter on
for more information. Some of the commands
are repeated here for clarity. Using S-Ring with multiple switches, it is recommended to do
the following:
1) On the switch which is the root node, authorize the use of S-Ring software
2) On the switch which is the root node or where the top of the ring ports are
configured, enable STP
3) On the root node enable S-Ring and add the necessary ports as S-Ring ports
4) On all other switches (except the root node), disable STP
5) On all other switches (except the root node), enable LLL
159