GarrettCom Magnum MNS-6K User Manual
Page 227
M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E
6K SNMP Agent supports all (v1/v2c/v3) versions.
Magnum6K25#
show snmp
SNMP v3 Configuration Information
=============================
System Name
: Magnum6K25
System Location
: Fremont, CA
System Contact
Authentication Trap
: Disabled
Default Trap Comm.
: public
V3 Engine ID
: 6K_v3Engine
Magnum6K25#
snmpv3
Switch over to SNMPv3 from this point forward
Magnum6K25(snmpv3)##
setvar sysname=my_m6k syscontact=admin syslocation=lab
Magnum6K25(snmpv3)#
quickcfg
This will enable default VACM.
Do you wish to proceed? [ 'Y' or 'N' ]
Y
Quick configuration done, default VACM enabled
Magnum6K25(snmpv3)##
engineid string=Magnum6K
Engine ID is set successfully
Magnum6K25(snmpv3)##
authtrap enable
Authentication trap status is set successfully
Magnum6K25(snmpv3)##
show-authtrap
Authentication Trap Status: Enabled
Magnum6K25(snmpv3)##
deftrap community=mysecret
Default trap community is set successfully
Magnum6K25(snmpv3)##
show-deftrap
Default Trap Community : public
Magnum6K25(snmpv3)##
trap add id=1 type=v1 host=10.21.1.100
Entry is added successfully
Max limit of system variables is
15 characters