5 installation requirements, Installation requirements, Mechanical check – Barco PDS-4K HDMI Presentation Switcher User Manual
Page 19: Environmental conditions, Rack-mount installation

19
R5912621 /01 PDS–4K
Product
Contains
Accessories included
•
4x 13-0210612-90
•
Screws to hold the rubber feet in place
•
B5631132
•
USB Thumb Drive (Contains Users Guide, System Software
and Control GUI)
•
R5912620
•
Safety manual
•
26-1802004-00
•
Quick Start Guide
•
26-0406065-00
•
Customer registration card
Mechanical check
This check should confirm that there are no broken parts and the unit is free of dents or scratches. Your Barco
Sales representative should be notified as soon as possible if this is not the case.
3.5 Installation requirements
Environmental conditions
The unit must always be mounted in a manner which ensures both air inlets and outlets are free. For
installations in environments where the device is subject to excessive dust, it is highly advisable to take
measures to prevent the dust from reaching the unit. If this is not a feasible, then the unit should be relocated
to a different dust-free location.
It is the customer's responsibility to ensure at all times that the device is protected from the harmful effects of
hostile airborne particles in the environment of the device. The manufacturer reserves the right to refuse repair
if a device has been subject to negligence, abandon or improper use.
The table below summarizes the physical environment in which the PDS– 4K presentation switcher may be
safely operated or stored.
Environment
Operating
Non-Operating
Ambient Temperature
0°C (32°F) to 40°C (104°F)
-10°C (14°F) to 60°C (140°F)
Air cleanliness
Clean office environment (equivalent
with cleanroom standard ISO 14644-1
ISO Class 9)
n.a.
Humidity
5% to 85% RH Non-Condensed
0% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
1
-60 (-197Ft) to 10000m (32810Ft)
Rack-mount installation
The PDS–4K chassis is designed to be rack mounted and is supplied with front rack-mount hardware.
The PDS–4K chassis can also be used in a “tabletop” configuration, without rack mounting.
When rack mounting the PDS–4K chassis, remember the following important points:
•
The PDS–4K chassis is 1.5 RU in height.
•
The maximum ambient operating temperature is 40°C (104°F).
•
Leave at least one inch of space (front and rear) to ensure that the airflow through the fan and vent holes is
not restricted.
•
When installing multiple units into a rack, distribute them evenly to prevent hazardous conditions that may
be created by uneven weight distribution.
•
Connect the unit only to a properly rated supply circuit.
1.
For PRC (People's Republic of China) the certified altitude is specified on the product label.